Details
Card for push button with display, suitable for the Kony, Major, Robur, Royal and Super Jolly 'E' Electronic doser models. See "More Information" above for installation instructions. This is version "S000SPU03/DQQ".
When the grinder is turned on for the first time after the replacement of the push-button card, you are asked to select the model of the grinder to set the corresponding times (0 - 1 - 2 - 3 - 4 - 5) and the display will show: No0
MODEL |
N° Model |
SINGLE DOSE (s) | DOUBLE DOSE (s) | THIRD DOSE (s) | MANUAL BUTTON FUNCTION |
Major, Robur, Royal, Stark, Kold Electronic | No0 | 1.5 | 2.7 | 4.5 | MANUAL |
Super Jolly Electtronic | No1 | 4 | 8 | 12 | MANUAL |
Mini Electronic A | No2 | 6 | 12 | 18 | MANUAL |
Kony Electronic | No3 | 3 | 5.4 | 9 | MANUAL |
Mini Filter | No4 | 7.5 | 14.5 | 22.5 | MANUAL |
Major, Robur, Royal, Stark, Kold Electronic | No5 | 1.5 | 2.7 | 4.5 | THIRD DOSE |
Use the + or - buttons to choose the desired N° model. To select the desired model press the MENU button. NOTE: No5 allows the manual button to fuction as a "second" third dose button, but only for the models listed.
If, by mistake, it is wrong to set the model, the grinder will still work normally but it will be necessary to enter the menu in order to set the desired times referring to the instruction manual for the programming instructions.