Details
Pump Protector Thermostat
Klixon® 2MM T100 thermal protector for vibratory pumps, rated to open at 100°C (212°F) with 60mm wire leads. Actual product appearance may vary by production run.
SPECIFICATIONS
- Type: Klixon 2MM T100
- Trip temperature: 100°C (212°F)
- Lead length: 60 mm
COMPATIBILITY
- Fits: vibratory pumps requiring a 100°C thermal protector
- Replaces: V_832
INSTALLATION
Simple DIY job, solder or crimp the leads in-line with the pump's power circuit.
PRO TIPS
- If a vibratory pump keeps cutting out after running for a while and then works again once it cools, that's the classic symptom of a tripped thermal protector, check for restricted water flow or a pump running dry before assuming the protector itself is bad.