110V 50/60Hz 9W 1/8" x 1/8" Two-way Parker Solenoid
This is the large body version. Uses W_635 Connector. Also available: C_289.
SKU | F_1856 |
---|---|
Manufacturer | Parker-Hannifin |
I have a Wega MiniNova which had an anti-vacuum valve not seating on initial heat up. As a result, water was spitting out the top. Water level probe was checked as well as the anti-vacuum valve and both were fine. Through conversations with Ryan, I removed the water level probe and the water level was at the very top of the boiler...So the boiler was over filling which decreased the head-space in the boiler. Water was spitting out because of the decreased head-space there wasn't enough room for the steam to build up enough pressure to seat the anti-vacuum valve. Ryan determined the culprit was possibly the Two-way Parker Solenoid leaking water through the Solenoid valve into the boiler. When I received the Solenoid valve and replaced it, my machine operated normally. My machine is now fixed...Thanks to Ryan.